Index of ITU-T Recommendations on CD-ROM

December 1998 - Published English edition


Series K - Protection against interference

File Size Date Recommendation title
K0005e.zip 21KB 06/64 K.5 - Joint use of poles for electricity distribution and for telecommunications
K0006e.zip 22KB 06/64 K.6 - Precautions at crossings
K0007e.zip 21KB 10/84 K.7 - Protection against acoustic shock
K0008e.zip 25KB 11/88 K.8 - Separation in the soil between telecommunication cables and earthing system of power facilities
K0009e.zip 21KB 10/68 K.9 - Protection of telecommunication staff and plant against a large earth potential due to a neighbouring electric traction line
K0010e.zip 74KB 10/96 K.10 - Low frequency interference due to unbalance about earth of telecommunication equipment
K0011e.zip 33KB 10/93 K.11 - Principles of protection against overvoltages and overcurrents
K0012e.zip 106KB 05/95 K.12 - Characteristics of gas discharge tubes for the protection of telecommunications installations
K0013e.zip 22KB 12/72 K.13 - Induced voltages in cables with plastic-insulated conductors
K0014e.zip 80KB 10/84 K.14 - Provision of a metallic screen in plastic-sheathed cables
K0015e.zip 25KB 12/72 K.15 - Protection of remote-feeding systems and line repeaters against lightning and interference from neighbouring electricity lines
K0016e.zip 507KB 12/72 K.16 - Simplified calculation method for estimating the effect of magnetic induction from power lines on remote-fed repeaters in coaxial pair telecommunication systems
K0017e.zip 88KB 11/88 K.17 - Tests on power-fed repeaters using solid-state devices in order to check the arrangements for protection from external interference
K0018e.zip 226KB 11/88 K.18 - Calculation of voltage induced into telecommunication lines from radio station broadcasts and methods of reducing interference
K0019e.zip 21KB 11/80 K.19 - Joint use of trenches and tunnels for telecommunication and power cables
K0020e.zip 68KB 10/96 K.20 - Resistibility of telecommunication switching equipment to overvoltages and overcurrents
K0021e.zip 55KB 10/96 K.21 - Resistibility of subscriber's terminal to overvoltages and overcurrents
K0022e.zip 39KB 05/95 K.22 - Overvoltage resistibility of equipment connected to an ISDN T/S bus
K0023e.zip 58KB 11/88 K.23 - Types of induced noise and description of noise voltage parameters for ISDN basic user networks
K0024e.zip 32KB 11/88 K.24 - Method for measuring radio-frequency induced noise on telecommunications pairs
K0025e.zip 81KB 05/96 K.25 - Protection of optical fibre cables
K0026e.zip 20KB 11/88 K.26 - Protection of telecommunication lines against harmful effects from electric power and electrified railway lines
K0027e.zip 181KB 05/96 K.27 - Bonding configurations and earthing inside a telecommunication building
K0028e.zip 69KB 03/93 K.28 - Characteristics of semi-conductor arrester assemblies for the protection of telecommunications installations
K0029e.zip 35KB 01/92 K.29 - Coordinated protection schemes for telecommunications cables below ground
K0030e.zip 37KB 03/93 K.30 - Positive temperature coefficient (PTc) thermistors
K0031e.zip 47KB 03/93 K.31 - Bonding configurations and earthing of telecommunication installations inside a subscriber's building
K0032e.zip 47KB 05/95 K.32 - Immunity requirements and test methods for electrostatic discharge to telecommunication equipment – Generic EMC Recommendation
K0033e.zip 89KB 10/96 K.33 - Limits for people safety related to coupling into telecommunications system from a.c. electric power and a.c. electrified railway installations in fault conditions
K0034e.zip 56KB 05/96 K.34 - Classification of electromagnetic environmental conditions for telecommunication equipment – Fast transient and radio-frequency phenomena
K0035e.zip 47KB 05/96 K.35 - Bonding configurations and earthing at remote electronic sites
K0036e.zip 34KB 05/96 K.36 - Selection of protective devices
K0037e.zip 32KB 10/96 K.37 - High frequency EMC mitigation techniques for telecommunication installations (Basic EMC recommendation)
K0038e.zip 57KB 10/96 K.38 - Radiated emission test procedure for physically large systems
K0039e.zip 52KB 10/96 K.39 - Risk assessment of damages to telecommunication sites due to lightning discharges
K0040e.zip 102KB 10/96 K.40 - Protection against LEMP in telecommunications centres
K0041e.zip 39KB 05/98 K.41 - Resistibility of internal interfaces of telecommunication centres to surge overvoltages
K0042e.zip 32KB 05/98 K.42 - Preparation of emission and immunity requirements for telecommunication equipment – General principles
K0043e.zip 95KB 05/98 K.43 - Immunity requirements for telecommunication equipment

[Top] [ITU Homepage] [Contents] [ITUTList] [ITUTSoft] [License] [Utilities]


Last modified: 23 oct 1998 by Electronic Publishing Service